翻訳と辞書
Words near each other
・ The Dallas Contemporary
・ The Dallas Guild
・ The Dallas Morning News
・ The Dallas Weekly
・ The Dalles 38C, Ontario
・ The Dalles Bridge
・ The Dalles Carnegie Library
・ The Dalles Chronicle
・ The Dalles Civic Auditorium
・ The Dalles Commercial Historic District
・ The Dalles Dam
・ The Dalles High School
・ The Dalles Military Road
・ The Dalles Mint
・ The Dalles, Oregon
The Dalmarnock fire tests
・ The Dalton Academy Warblers
・ The Dalton Girls
・ The Daltons (Lucky Luke)
・ The Dam Busters
・ The Dam Busters (book)
・ The Dam Busters (film)
・ The Dam Busters (video game)
・ The Dam Busters March
・ The Dam Keeper
・ The Dam on the Yellow River
・ The Dam Short Film Festival
・ The Damage
・ The Damage (Marillion song)
・ The Damage a Man Can Do


Dictionary Lists
翻訳と辞書 辞書検索 [ 開発暫定版 ]
スポンサード リンク

The Dalmarnock fire tests : ウィキペディア英語版
The Dalmarnock fire tests

The Dalmarnock fire tests are a series of fire experiments that were conducted in a real high-rise building in the United Kingdom.
In 2006, the BRE Centre for Fire Safety Engineering at the University of Edinburgh, conducted this series of large-scale fire tests in a high-rise building in collaboration with the BBC series ''Horizon'', EPSRC, Glasgow Housing Association, Strathclyde Fire Brigade, Glasgow Caledonian University, Lion TV, Arup, BRE, Xtralis and Powerwall Systems Ltd, among other contributors.
==Description==
The building, a 23-storey reinforced-concrete tower located at 4 Millerfield Place in Dalmarnock, Glasgow, was scheduled for demolition and hence was evacuated of tenants. Three main experiments were conducted over two days, from 25 to 26 July 2006. Tests One and Two took place in identical flats, the main compartment of which had been fitted with regular living room and office furniture, arranged to provide conditions that favour repeatability. Test Three was a smaller smoke management experiment held in one of the two main emergency exit stairwells.
Tests One and Two were fully instrumented with a high sensor density, including measurements of temperature, incident heat, gas velocities, smoke obscuration, wall temperature and structure deflection, among others. The tests varied in that Test One allowed the fire to develop freely to post-flashover conditions, while Test Two incorporated sensor-informed ventilation management and was extinguished before post-flashover conditions were attained. Both tests had approximately 300 sensors monitoring several different characteristics of the fire environment, but Test One had about 160 additional sensors monitoring the structural response.
These experiments endeavoured to establish a highly monitored fire in a realistic residential scenario, allowing for several different modern fire safety engineering tools to be tested. The comprehensive set of data collected is being used for validation of different mathematical models of fire dynamics. Because the data has a spatial resolution high enough to be comparable to typical resolutions of CFD fire models, the tests are specially well suited for validation of this type of models. The tests also form an integral part of the research conducted for the FireGrid research project,〔(【引用サイトリンク】title=FireGrid Project )〕 that is, the development of emergency control systems that use continuous sensor data and computer modelling, to provide forecast of the fire evolution and aid the efficient deployment of resources.

抄文引用元・出典: フリー百科事典『 ウィキペディア(Wikipedia)
ウィキペディアで「The Dalmarnock fire tests」の詳細全文を読む